Deep wells

True experts in deep wells

More than 20 years of successful projects

Benefits

Ícono de cuadrilla

Own installation and maintenance team

Ícono de licitaciones

Involvement in high-quality biddings

Ícono de sucursal

We have a marketing branch in Monterrey

Ícono de empresa

Solid and
trustworthy company

Ícono de ficha técnica

We have detailed technical sheets

Ícono de cotización

Customized quotes according to your projects

Ícono de envío a domicilio

Home delivery

Our numbers provide certainty

of an excellent and high-quality service
502
performed services
20
years of experience
98
attended wells

Certifications

We do more than necessary for the satisfaction of our clients, that is why our staff is trained and specialized in:

Ícono de reparación

Repairs

Ícono de instalación

Installation

Ícono de arranque

Start-up and operation

Ícono de cálculo

Calculation and selection

Certifications

We do more than necessary for the satisfaction of our clients, that is why our staff is trained and specialized in:

Only the best brands

Services

Equipment acquisition

Equipment acquisition

We arrive at the site with all the specialized equipment to perform the installation. Once the crane is placed, we make the coupling of the pump with the motor, apply the waterproof wiring tie, and then install the pump, then the tubing, along with the cable, until we reach the discharge head. Once all this is done, we start the equipment for the first time to ensure that everything is working correctly. We verify rotation, water flow, electrical values, ​​and dynamic level.

Foto del equipamiento de Power Depot

Previous requirements

Well diameter

ADEME (casing) diameter

Operation’s voltage

Work water flow

Well levels

This is the process to be performed

Supply

Cable and tubing

Valves

Tubing

Electrical starter

Discharge train

Start-up and operation

Electrification

Renewable energy

Diagnosis

Pumping capacity

It helps to identify the amount of water produced by the well as well as the depth of its drawdown. We do this by pumping at a controlled speed for 24, 48 or 72 hours. At the end we deliver the tabulated and graphed results.

Foto del equipo de diagnóstico de power Depot

Previous requirements

Well diameter

Diameter of the discharge tubing

Total depth
of the well

This is the process to be performed

Installation of submergible moto pump

Equipment start-up

Flow measurement

Level measurement

Delivery of results

Diagnose

Video recording of wells

To have real and certain information on the conditions of a well, video inspection with a specialized camera is necessary, which will allow us to evaluate and identify problems in its structure, such as collapses of different kinds and we can even observe if the grooves in the ADEME (casing) are clogged with embeddings formed by minerals inside and we can determine the static water level (water surface).

Foto de personal de Power Depot realizando una videograbación de pozo

Previous requirements

Diámetro del pozo

ADEME (casing) diameter

Location of the well

This is the process to be performed

Installation of the chamber

Video recording of the well

Delivery of results and recording

Automation and pumping system

Automation of deep wells

We install the control panel, then we install the protections for both the well and the final point. Then we will install filling valves (if necessary) and finally, we perform the equipment tests and begin the start-up.

Foto de tablero de control de Power Depot

Previous requirements

Caballaje

Horsepower

Voltaje

Available voltage

Tubing diameter

Variable a controlar

Variable to control

Número de bombas

Number of pumps

This is the process to be performed

Board installation

Installation of sensors

Installation of valves

Floats

Automation and pumping system

Automation of the pumping system

We insert the equipment in the control room, then we do the power supply wiring (on the switch and motor pump side). We install a pressure sensor (depending on the variable that you want to control). Then we program the frequency converter to your needs and then we finish by performing functional tests and the start-up.

Cuarto de control de Power Depot

Previous requirements

Voltaje

Voltage in operation

Caballaje

Motor’s horsepower

Transformer’s capacity

Defined variable to control

This is the process to be performed

Insertion

Entry and exit wiring

Programming

Start-up and operation

Automation and pumping system

Installation of control boards

We install the components of each board in our Authorized Service Facility according to the highest quality standards and complying with the technical requirements, for example: NEMA enclosure or IP requirements, protection against transients, corrosive, marine environments, among others

Foto de personal de Power Depot manipulando tablero de control

Previous requirements

Caballaje

Horsepower

Voltaje

Voltage

Tubing diameter

Variable to control

Number of pumps

This is the process to be performed

Insertion

Entry and exit wiring

Programming

Start-up and operation

Automation and pumping system

Repumping of clean and wastewater

We install the equipment to re-pump clean water or wastewater, then we automate it through a control board, where level “pears” are used as protection and automation. Finally, we perform tests and start the equipment.

Foto de personal de Power Depot realizando Rebombeo de agua limpia y aguas residuales

Previous requirements

Caballaje

Horsepower

Voltaje

Voltage

Tubing diameter

Water type

Number of pumps

This is the process to be performed

Installation of equipment

Board automation

Installation of sensors

Tests

Start-up and operation

Special services

Protection and retrieval of equipment

We uninstalled the pumping equipment and then made a video recording to inspect the conditions of the well. Subsequently, we identify the damaged areas and proceed to repair them by means of a casing protection. This process lasts 3 days (depending on the meters to be repaired). We make a video recording again to ensure the optimal repair of the water well. The procedure is completed by installing the pumping equipment and begin start-up.

Foto de personal de Power Depot realizando Encasquillado y pesca de equipo

Previous requirements

Uninstallation of equipment

Video recording

This is the process to be performed

Uninstalla-tion of equipment

Initial video

Protection

Final video

Installation of the pump equipment

Start-up and operation

Special services

Disinfection

Disinfection is an important stage within the water treatment process. It helps in the effective destruction of pathogenic microorganisms. It is not toxic for humans or pets (at the used doses), it is non-toxic for aquatic and plant species (at the used doses); it produces ease and safety in storage, transportation and operation, stability over time for the active substance, an easy and reproducible analysis of concentration in water; it provides residual protection in the water during distribution (stability of the residual for hours/days), it eliminates biofilms from the tubing (at the used doses).

We verify the following factors that may affect this procedure:

  • Biolayers in the tubing: impact on the ability of disinfection and cross-contamination of product biolayers.
  • Corrosion inside the layer.
  • Chemical composition of water: it could be organic matter (natural or microorganisms) or inorganic matter (iron, magnesium, nitrates, arsenic). Disinfection can be applied through these systems: physical: radiation, UV, ultrafiltration; chemical: ozone, chlorine gas, sodium hypochlorite, chlorine dioxide.
Foto del equipo de desinfección de Power Depot

Previous requirements

Product and attributes to disinfect

This is the process to be performed

Hydraulic and electrical installation of the equipment

Start-up and operation

Special services

Dosage

The dose regulating pump provides an exact specific flow from one liquid to another fluid (hazardous, concentrated, degassing or highly viscous liquids) over an established period of time. It represents low costs in energy, pump life cycle and maintenance.

Foto del equipo de Dosificación de Power Depot

Previous requirements

Product dose to be regulated

Flow to be regulated

Pressure

Voltaje

Voltage

This is the process to be performed

Hydraulic and electrical installation of the equipment

Start-up and operation

Special services

Foto de personal de Power Depot realizando electrificación
Foto de personal de Power Depot realizando electrificación

Electrification

We have 3 services in the field of well electrification.

Power Supply in Medium Voltage Networks

We improve the distribution of electrical energy; to achieve this we generate a process in which the following is carried out: overhead lines, transitions, power supply to underground and overhead substations.

Electrical
Substations

We establish the adequate levels for the transmission and distribution of electrical energy; to do this we provide supply and installation as well as maintenance of pole and pedestal type transformers. We also design compact substations.

Emergency Plants:

We provide solutions in power supply for heavy duty applications and jobs; for this we have rental and sale of emergency plants completely designed to your needs.

Maintenance

Energy quality study

Upon entering the facilities, we connect different sensor types to the equipment, in order to monitor all electrical values ​​for 3 consecutive days. Once these tests have been performed, we deliver a report with graphs and provide recommendations for improvements

Foto de personal de Power Depot realizando un Estudio de calidad de energía

Previous requirements

Voltaje

Availability of installations

This is the process to be performed

Sensor installation

Monitoring

Delivery of results

Maintenance

Maintenance of pumping equipment

At our Authorized Service facility, we perform tests on the pumping equipment and with the diagnosis we perform repair or maintenance tasks to guarantee optimal performance.

Foto de personal de Power Depot realizando Mantenimiento a equipo de bombeo

Previous requirements

Uninstallation of equipment*

Analysis of installations

*Cost not included in the maintenance service

This is the process to be performed

Electrical tests and disassembly

Assembly

Repair or maintenance

Reinstallation

Maintenance

Restoration of wells

We perform a video evaluation and then apply chemicals for deep cleaning of the well (descaling of rust and scale from the ADEME (casing) pipe). Continuing with the vertical brushing of the well installations, we uncover the well veins and finally we "spoon" all the dirt found at the bottom of the water well. We deliver the results and video recording.

Foto de pozo de agua rehabilitado por Power Depot

Previous requirements

Diameter

Total depth of the well

Well ADEME (casing) location and material

This is the process to be performed

Application of descaling chemicals

Brushed

Spooning

Pistoning

Desilting

Final video

Project delivery

Perforation

Perforation

We evaluate the terrain through geological studies carried out by experts in the field. This geothermal mapping allows us to know the depth at which the water tributary is located. We determine the best location to make the perforation of the water well and then we make the perforation using the most advanced equipment according to the type of terrain material. Once done, we apply the ADEME (casing) and gravel. Finally, we generate a video recording of the facilities.

Foto de personal de Power Depot realizando perforación

Previous requirements

Ubicación del pozo

ADEME (casing) diameter

Geological study

This is the process to be performed

Geological analysis

Determination of the installation point

Surface perforation

Tubing application

Gauge study

Video recording